CONTINUOUS DATA OUTPUT FORMATS, CONT.
RANGER 5000 FORMAT A
Beginning with version 2.6.1 of the firmware, the Ranger 5000 Format A has been added to
the Continuous Data Output Formats. In setup, select type 9 for the Ranger 5000 format.
At the StArtb prompt, enter the decimal value for the start character.
Valid entry is 0 to 126.
At the Endb 1 prompt, enter the decimal value for the first end character.
Valid entry is 0 to 126.
At the Endb 2 prompt, enter the decimal value for the second end character.
Valid entry is 0 to 126.
If the above items are ‘0’ then the character will not be included in the data stream.
Format
<StArtb>Sign WeightA(7) Status
Where,
Sign is the sign of the weight (‘ ‘ for positive, ‘-‘ for negative)
WeightA is a seven character string containing the current weight including the
decimal point. If there is no decimal point, then the first character is a
space. Leading zero blanking applies.
Status provides information on the weight reading. The characters G/N/U/O/M/E
represent Gross/Net/Underload/Overload/Motion/Error respectively.
200, 205, 210 and 215 Rev 2.6.1 Addendum