Strona 1 - 210 and 215

8200-M411-O1 Rev D y 210/215 Installation & Technical 1 210 and 215 WEIGHT INDICATOR Installation and Technical Manual

Strona 2

8200-M411-O1 Rev D y 210/215 Installation & Technical 6 INSTALLATION Before beginning installation of your Model 210/215 Weight Indicator, make ce

Strona 3 - PRECAUTIONS

8200-M411-O1 Rev D y 210/215 Installation & Technical 7 CAUTION! Disconnect any external load cell power supply before connecting load cells to

Strona 4 - FCC COMPLIANCE STATEMENT

8200-M411-O1 Rev D y 210/215 Installation & Technical 8 INSTALLATION, CONT. Load Cell Cable Shield Wire Connection for RFI Suppression 1. After a

Strona 5 - SPECIFICATIONS

8200-M411-O1 Rev D y 210/215 Installation & Technical 9 INSTALLATION, CONT. Serial I/O Cable Installation The 210/215 indicators may be connected

Strona 6 - SPECIFICATIONS, CONT

8200-M411-O1 Rev D y 210/215 Installation & Technical 10 INSTALLATION, CONT. For completely isolated outputs, J11 must be open (positioned on one

Strona 7

8200-M411-O1 Rev D y 210/215 Installation & Technical 11 INSTALLATION, CONT. Main PCB Figure No. 8

Strona 8

8200-M411-O1 Rev D y 210/215 Installation & Technical 12 INSTALLATION, CONT. Main PCB Jumpers J1 - BATTERY CHARGE MODE (210 Only) Place jumper J1

Strona 9 - Transient Suppression

8200-M411-O1 Rev D y 210/215 Installation & Technical 13 KEYPAD FUNCTIONS The Model 210/215 is equipped with a 22-key keypad. The keypad is used

Strona 10 - INSTALLATION

8200-M411-O1 Rev D y 210/215 Installation & Technical 14 KEYPAD FUNCTIONS, CONT. ON/OFF KEY This key performs two functions. Pressing it when the

Strona 11 - INSTALLATION, CONT

8200-M411-O1 Rev D y 210/215 Installation & Technical 15 KEYPAD FUNCTIONS, CONT. Consecutive Number If the consecutive number displayed is correc

Strona 12

8200-M411-O1 Rev D y 210/215 Installation & Technical 2

Strona 13

8200-M411-O1 Rev D y 210/215 Installation & Technical 16 KEYPAD FUNCTIONS, CONT. The 210/215 includes support for visual tickets. Visual tickets

Strona 14

8200-M411-O1 Rev D y 210/215 Installation & Technical 17 KEYPAD FUNCTIONS, CONT. ASTERISK KEY This key is used for several functions. During Set

Strona 15

8200-M411-O1 Rev D y 210/215 Installation & Technical 18 ANNUNCIATORS Annunciators are turned on to indicate that the display is in the mode corre

Strona 16

8200-M411-O1 Rev D y 210/215 Installation & Technical 19 ANNUNCIATORS OVER/PWC3 (210 Only) This annunciator is used to signal that the displayed

Strona 17 - KEYPAD FUNCTIONS

8200-M411-O1 Rev D y 210/215 Installation & Technical 20 SETUP AND CALIBRATION Your Model 210/215 indicator has been thoroughly tested and calibra

Strona 18 - KEYPAD FUNCTIONS, CONT

8200-M411-O1 Rev D y 210/215 Installation & Technical 21 SETUP AND CALIBRATION, CONT. Pressing the calibration switch at any prompt will return y

Strona 19

8200-M411-O1 Rev D y 210/215 Installation & Technical 22 SETUP AND CALIBRATION, CONT. !;> (Legal For Trade) Press the ENTER key to show the cu

Strona 20

8200-M411-O1 Rev D y 210/215 Installation & Technical 23 SETUP AND CALIBRATION, CONT. $> (Capacity) Press the ENTER key to show the current

Strona 21

8200-M411-O1 Rev D y 210/215 Installation & Technical 24 SETUP AND CALIBRATION, CONT. 3`6';`> X, Y (Digital Output) Press the ENTER key to

Strona 22

8200-M411-O1 Rev D y 210/215 Installation & Technical 25 SETUP AND CALIBRATION, CONT. `6> (Auto Shutoff) The Automatic Shutoff feature will

Strona 23

8200-M411-O1 Rev D y 210/215 Installation & Technical ITABLE OF CONTENTS SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 24 - SETUP AND CALIBRATION

8200-M411-O1 Rev D y 210/215 Installation & Technical 26 SETUP AND CALIBRATION, CONT. `@`3 (`@`3) - Analog to Digital Filtering 3!;> (Digit

Strona 25 - SETUP AND CALIBRATION, CONT

8200-M411-O1 Rev D y 210/215 Installation & Technical 27 SETUP AND CALIBRATION, CONT. FILTER SETTING RECOMMENDATIONS Non Critical Sample Rate If

Strona 26

8200-M411-O1 Rev D y 210/215 Installation & Technical 28 SETUP AND CALIBRATION, CONT. ! (!) - Calibration With ! (!) displayed, press th

Strona 27

8200-M411-O1 Rev D y 210/215 Installation & Technical 29 SETUP AND CALIBRATION, CONT. Dual-Point with Zero (First Zero) Calibration !> – Fi

Strona 28

8200-M411-O1 Rev D y 210/215 Installation & Technical 30 SETUP AND CALIBRATION, CONT. Dual-Point without Zero (False Zero) Calibration !> –

Strona 29

8200-M411-O1 Rev D y 210/215 Installation & Technical 31 SETUP AND CALIBRATION, CONT. Single-Point for Zero Only (Only Zero) Calibration !>

Strona 30

8200-M411-O1 Rev D y 210/215 Installation & Technical 32 SETUP AND CALIBRATION, CONT. *-6 (*-6) - Serial Input/Output With *-6 (*-6) displayed,

Strona 31

8200-M411-O1 Rev D y 210/215 Installation & Technical 33 SETUP AND CALIBRATION, CONT. If SMA is selected, the data will be transmitted in the fol

Strona 32 - CALIBRATION MODES

8200-M411-O1 Rev D y 210/215 Installation & Technical 34 SETUP AND CALIBRATION, CONT. If WI110 is selected, the data will be transmitted in the fo

Strona 33

8200-M411-O1 Rev D y 210/215 Installation & Technical 35 SETUP AND CALIBRATION, CONT. ;9:> (Threshold Weight) Press the ENTER key to show the

Strona 34

8200-M411-O1 Rev D y 210/215 Installation & Technical II FCC COMPLIANCE STATEMENT WARNING! This equipment generates uses and can radiate radio fr

Strona 35

8200-M411-O1 Rev D y 210/215 Installation & Technical 36 SETUP AND CALIBRATION, CONT. $9-0; ($9-0;) - Print Tab Settings With $9-0; ($9-0;) disp

Strona 36

8200-M411-O1 Rev D y 210/215 Installation & Technical 37 SETUP AND CALIBRATION, CONT. 0;> (Net Weight Print Location) Press the ENTER key to

Strona 37

8200-M411-O1 Rev D y 210/215 Installation & Technical 38 SETUP AND CALIBRATION, CONT. `*$0 (*$0) - Fine Span Adjustment NOTE! The *$0 and

Strona 38

8200-M411-O1 Rev D y 210/215 Installation & Technical 39 SETUP REVIEW The 210/215 indicators allow several operational parameters to be reviewed

Strona 39

8200-M411-O1 Rev D y 210/215 Installation & Technical 40 ACCUMULATORS To view the NET accumulator: 1. Press the ASTERISK key then the NET/GROSS

Strona 40

8200-M411-O1 Rev D y 210/215 Installation & Technical 41 BEFORE YOU CALL FOR SERVICE The 210/215 indicators have been designed to provide you wit

Strona 41

8200-M411-O1 Rev D y 210/215 Installation & Technical 42 ERROR CODES The 210/215 indicators are equipped with software that indicates when an erro

Strona 42

8200-M411-O1 Rev D y 210/215 Installation & Technical 43 ERROR CODES, CONT. < (HuH?) UNITS key pressed in an attempt to perform a unit conv

Strona 43 - CALIBRATION “C” NUMBERS

8200-M411-O1 Rev D y 210/215 Installation & Technical 44 AXLE WEIGHER MODE OPERATION After placing the wheel load weighers on the ground in front

Strona 44 - ACCUMULATORS

8200-M411-O1 Rev D y 210/215 Installation & Technical 45 AXLE WEIGHER MODE OPERATION, CONT. Additional Features If you wish to also record the to

Strona 45 - BEFORE YOU CALL FOR SERVICE

8200-M411-O1 Rev D y 210/215 Installation & Technical 1 SPECIFICATIONS Unless otherwise noted, the specifications apply to both the Model 210 and

Strona 46 - ERROR CODES

8200-M411-O1 Rev D y 210/215 Installation & Technical 46 PART IDENTIFICATION (210 Rear Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPT

Strona 47 - CALIBRATION SEAL INSTALLATION

8200-M411-O1 Rev D y 210/215 Installation & Technical 47 PART IDENTIFICATION (210 Rear Enclosure Sub Assembly)

Strona 48 - AXLE WEIGHER MODE OPERATION

8200-M411-O1 Rev D y 210/215 Installation & Technical 48 PART IDENTIFICATION (210 Front Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIP

Strona 49 - Additional Features

8200-M411-O1 Rev D y 210/215 Installation & Technical 49 PART IDENTIFICATION (210 Final Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 1 593G

Strona 50 - PART IDENTIFICATION

8200-M411-O1 Rev D y 210/215 Installation & Technical 50 PART IDENTIFICATION (215 Rear Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPT

Strona 51

8200-M411-O1 Rev D y 210/215 Installation & Technical 51 PART IDENTIFICATION (215 Rear Enclosure Sub Assembly)

Strona 52

8200-M411-O1 Rev D y 210/215 Installation & Technical 52 PART IDENTIFICATION (215 Front Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIP

Strona 53

8200-M411-O1 Rev D y 210/215 Installation & Technical 53 PART IDENTIFICATION (215 Final Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 1 593G

Strona 54

8200-M411-O1 Rev D y 210/215 Installation & Technical 54

Strona 55

8200-M411-O1 Rev D y 210/215 Installation & Technical 55 APPENDIX A: MODEL 210DC AND 215DC The Models 210DC and 215DC have been created to change

Strona 56

8200-M411-O1 Rev D y 210/215 Installation & Technical 2 SPECIFICATIONS, CONT. Unless otherwise noted, the specifications apply to both the Model

Strona 57

8200-M411-O1 Rev D y 210/215 Installation & Technical 1 STATEMENT OF LIMITED WARRANTY WARRANTY TERMS Cardinal Scale Manufacturing Company warrant

Strona 58

8200-M411-O1 Rev D y 210/215 Installation & Technical 2 PRODUCT TYPE TERM MATERIAL AND WORKMANSHIP LIGHTNING DAMAGE See note 9 WATER DAMAGE See n

Strona 59 - MODEL 210DC AND 215DC

8200-M411-O1 Rev D y 210/215 Installation & Technical 3 APPLICABLE LIMITATIONS AND REQUIREMENTS 1. This warranty applies only to the original pur

Strona 60 - WARRANTY TERMS

8200-M411-O1 Rev D y 210/215 Installation & Technical 4 EXCLUSIONS This warranty does not include replacement of consumable of expendable parts.

Strona 61

Addendum to the 200, 205, 210 and 215 Installation and Technical Manual TEST MODE This addendum is to inform you of the TEST MODE feature in the 200,

Strona 62

Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig

Strona 63

CONTINUOUS DATA OUTPUT FORMATS TOLEDO Beginning with version 2.6.1 of the firmware, the Toledo output has been expanded to provide a selection between

Strona 64 - TEST MODE

CONTINUOUS DATA OUTPUT FORMATS, CONT. RANGER 5000 FORMAT A Beginning with version 2.6.1 of the firmware, the Ranger 5000 Format A has been added to th

Strona 65 - IMPORTANT!

200, 205, 210 and 215 Rev 2.6.1 Addendum 4 CONTINUOUS DATA OUTPUT FORMATS, CONT. GEDGE 1650 FORMAT 4 Beginning with version 2.6.1 of the firmware, the

Strona 66 - Long Format:

Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig

Strona 67 - RANGER 5000 FORMAT A

8200-M411-O1 Rev D y 210/215 Installation & Technical 3 EUROPEAN DECLARATION OF CONFORMITY Manufacturer: Cardinal Scale Manufacturing Company P

Strona 68 - GEDGE 1650 FORMAT 4

8200-M411-O1 Rev D y 210/215 Installation & Technical 1

Strona 69 - 200, 205, 210 and 215

8200-M411-O1 Rev D y 210/215 Installation & Technical 4 PRECAUTIONS Static Electricity CAUTION! This device contains static sensitive circuit ca

Strona 70

8200-M411-O1 Rev D y 210/215 Installation & Technical 5 SITE PREPARATION REQUIREMENTS, CONT. Electrical Power The 210/215 indicators have been de